Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arthroplast Today ; 21: 101134, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37193537

RESUMEN

Background: Instability is a common indication for revision after total knee arthroplasty. Replacement of multiple components is the current standard, but isolated polyethylene liner exchange (IPE) may present a less-morbid alternative. This study aims to determine (1) whether IPE results in similar rerevision frequency to component revision in select patients with symptomatic instability and (2) the effect of increasing constraint on the outcome. Methods: We retrospectively reviewed 117 patients revised for symptomatic total knee arthroplasty instability from January 2016 to December 2017. The component revision (60 patients) or IPE (57 patients) cohorts were further stratified based on whether constraint was increased or not. The primary objective was to compare rerevision rates 2 years after component revision vs IPE. The secondary objectives consisted of evaluating reasons for rerevision, preoperative and postoperative patient-reported outcome measures, and range of motion. Results: The rerevision rate was 18%, with no statistical difference between component and IPE cohorts. Cases where level of constraint increased due to revision, a significantly lower rate of rerevision was detected (9 of 77) (12%) than in cases where constraint did not increase (12 of 39) (31%) (P=0.012). This association was also noted in the component revision cohort but not in the IPE cohort (P=0.011). Conclusions: Rerevision occurred at similar frequencies 2 years after IPE or component revision for total knee arthroplasty instability. For component revision, increased constraint was associated with significantly fewer rerevisions.

2.
J Arthroplasty ; 38(6S): S368-S373, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36801475

RESUMEN

BACKGROUND: The etiology of anterior knee pain after total knee arthroplasty (TKA) remains unclear. Few studies have examined patellar fixation quality. The purpose of the present study was to evaluate the patellar cement-bone interface after TKA on magnetic resonance imaging (MRI) and to correlate the patella fixation grade with the incidence of anterior knee pain. METHODS: We retrospectively reviewed 279 knees undergoing metal artifact reduction MRI for either anterior or generalized knee pain at least 6 months after cemented, posterior-stabilized TKA with patellar resurfacing with one implant manufacturer. MRI cement-bone interfaces and percent-integration of the patella, femur, and tibia were assessed by a fellowship-trained senior musculoskeletal radiologist. The grade and character of the patella interface were compared to the femur and tibia. Regression analyses were used to determine the association between patella integration with anterior knee pain. RESULTS: There were more patellar components with ≥75% zones of fibrous tissue (50%) compared to the femur (18%) or tibia (5%) (P < .001). There were a greater number of patellar implants with poor cement integration (18%) compared to the femur (1%) or tibia (1%) (P < .001). MRI findings showed more evidence of patellar component loosening (8%) compared to the femur (1%) or tibia (1%) (P < .001). Anterior knee pain was correlated with worse patella cement integration (P = .01), with women predicted to have better integration (P < .001). CONCLUSION: The quality of the patellar cement-bone interface after TKA is worse compared to the femoral or tibial component interface. Poor patellar cement-bone interface may be a source of anterior knee pain after TKA, but further investigation is required.


Asunto(s)
Prótesis de la Rodilla , Rótula , Humanos , Femenino , Rótula/diagnóstico por imagen , Rótula/cirugía , Rótula/patología , Tibia/diagnóstico por imagen , Tibia/cirugía , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Dolor , Cementos para Huesos
3.
J Arthroplasty ; 38(6S): S190-S195, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813213

RESUMEN

BACKGROUND: Knee instability is a leading cause of dissatisfaction following total knee arthroplasty (TKA). Instability can involve abnormal laxity in multiple directions including varus-valgus (VV) angulation, anterior-posterior (AP) translation, and internal-external rotation (IER). No existing arthrometer objectively quantifies knee laxity in all three of these directions. The study objectives were to verify the safety and assess reliability of a novel multiplanar arthrometer. METHODS: The arthrometer utilized a five degree-of-freedom instrumented linkage. Two examiners each conducted two tests on the leg that had received a TKA of 20 patients (mean age 65 years (range, 53-75); 9 men, 11 women), with nine and eleven distinct patients tested at 3-month and 1-year postoperative time points, respectively. AP forces from -10 to 30 Newtons, VV moments of ±3 Newton-meters, and IER moments of ±2.5 Newton-meters were applied to each subject's replaced knee. Severity and location of knee pain during testing were assessed using a visual analog scale. Intraexaminer and interexaminer reliabilities were characterized using intraclass correlation coefficients. RESULTS: All subjects successfully completed testing. Pain during testing averaged 0.7 (out of possible 10; range, 0-2.5). Intraexaminer reliability was >0.77 for all loading directions and examiners. Interexaminer reliability and 95% confidence intervals were 0.85 (0.66-0.94), 0.67 (0.35-0.85), and 0.54 (0.16-0.79) in the VV, IER, and AP directions, respectively. CONCLUSION: The novel arthrometer was safe for evaluating AP, VV, and IER laxities in subjects who had received TKA. This device could be used to examine relationships between laxity and patient perceptions of knee instability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Masculino , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Reproducibilidad de los Resultados , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular
5.
J Arthroplasty ; 37(8S): S830-S835.e3, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35151806

RESUMEN

BACKGROUND: Pain catastrophizing, anxiety, and depression are associated with poor outcomes after total hip (THA) and total knee (TKA) arthroplasty. The goal of this study is to determine the relationship between post-operative pain scores and opioid consumption; and the association among pre-operative measures of anxiety, depression, and pain catastrophizing and post-operative opioid consumption in patients undergoing THA and TKA. METHODS: This is a single-institution prospective cohort study of 243 opioid-naïve patients undergoing elective, primary THA (n = 123) or TKA (n = 120) for osteoarthritis. Pre-operatively, patients completed the PROMIS-29 (Patient-Reported Outcomes Measures Information System; physical function/anxiety/depression/fatigue/sleep disturbance/social activities/pain interference/pain intensity) and Pain Catastrophizing Scale. Post-operatively, patients completed a weekly survey for 12 weeks determining morphine-milligram-equivalent (MME) opioid consumption, opioid cessation, and visual analog scale pain scores. Multivariable regression models determined the association between pre-operative scores and post-operative opioid consumption. RESULTS: Mean (±standard deviation) total opioid consumption and duration was 75.1 ± 112.0 MME and 1.7 ± 1.7 weeks in THA and 384.7 ± 473.3 MME and 4.3 ± 3.5 weeks in TKA. Visual analog scale pain scores (0-100) after opioid cessation were 28.0 ± 22.9 in THA and 30.7 ± 25.8 in TKA. Multivariable regression showed that each unit increase in PROMIS-29 fatigue T-score was associated with 8.4 hours longer opioid usage in THA (P = .008) and 15.1 hours longer in TKA (P = .036), as well as 12.7 MME additional opioids in TKA (P = .027). There were no significant associations with other PROMIS-29 domains or the Pain Catastrophizing Scale. CONCLUSION: Opioid use duration is different for THA and TKA and may correlate with pain scores. Only pre-operative fatigue was associated with post-operative opioid consumption. These findings should inform THA and TKA post-operative pain management pathways.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Cuidados Posteriores , Analgésicos Opioides/uso terapéutico , Fatiga , Humanos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología , Alta del Paciente , Estudios Prospectivos
6.
JBJS Case Connect ; 11(3)2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34449446

RESUMEN

CASE: This report describes a case of an unstable spine fracture in the setting of severe degenerative disc disease in a patient who underwent a direct anterior total hip arthroplasty (THA). The patient was positioned supine on a standard operating room table and postoperatively complained of back pain and neurologic deficits. Advanced imaging identified a T12-L1 extension-distraction injury, and the patient ultimately required surgical decompression and spinal fusion. CONCLUSION: This case outlines a serious complication of THA that can occur in patients with degenerative spine disease and highlights the importance of taking precautions to reduce stress on the spine during surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas de la Columna Vertebral , Fusión Vertebral , Artroplastia de Reemplazo de Cadera/efectos adversos , Descompresión Quirúrgica , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/etiología , Fracturas de la Columna Vertebral/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...